CCUSE "Laboratory of biosafety, quality of food products and food safety"
Center for collective use of scientific equipment


The list of available orders for equipment of the CCUSE

Total: 5

received
Request ID: req.g8syes
Estimated cost

17.25 thousands of euros

Functional purpose of the equipment

Qualitative and quantitative characteristics of food products, raw materials and other materials

Motivation of the need for equipment

To analyze and control the quality of raw materials, semi-finished products and finished products according to the appropriate methods


received
Request ID: req.m68cst
Estimated cost

39.02 thousands of euros

Functional purpose of the equipment

Equipping the Kinexus Pro+ rotary rheometer with additional parallel plates-geometries will allow to expand the measurement range of a wide range of materials, for Newtonian and non-Newtonian fluids with low viscosity to more viscous dispersed systems: gel-like materials, soft and hard substances, polymers and others systems The wide range of plate sizes is due to the measurement of materials with different rheological parameters.

Motivation of the need for equipment

Smaller diameter geometries are used for samples with high viscosity, and larger ones (Ø50 mm) for materials with low viscosity (0.1 Pa*s). In addition, geometries with a toothed surface are used to study emulsions and suspensions, which are prone to slipping. This manifests as an early drop in viscosity during shear rate measurement, resulting in a sudden drop in viscosity and suspected slippage. This surface interface provides additional adhesion of the material to the geometry, and stimulates the smooth flow of the material. Using geometries of different diameters will allow for a more smooth variation of the gaps between the geometries in the measurement and follow general rules of thumb, and will provide sufficient interaction to eliminate wall effects that cause artifacts in the results. The possibility of combining the geometries of the cone and the plate will allow to measure the geometries at the set gap (automatically controlled by the software). This allows absolute viscosity to be measured when the entire sample is subjected to the same shear rate, a significant advantage over parallel plate geometries that have a range of shear rates along their radii and only the average value is reported. For the study of materials and systems sensitive to temperature effects, or in which phase changes/transitions occur under the influence of temperature, elimination of temperature gradients, and when measuring temperatures significantly higher or lower than the ambient temperature, a cartridge is needed for setting temperatures when measuring from -5C up to 180°C, or from -40°C with an active heat exchanger. The cartridge is a combination of a Peltier element with additional heaters for active control of radial and vertical heat losses from the local environment of the sample with a resolution of 0.01°C, with measurement stability of +/- 0.1°C.


received
Request ID: req.c288e1
Estimated cost

74.34 thousands of euros

Functional purpose of the equipment

For the dynamic formation of the image of particles, and obtaining an idea of ​​the dispersion of particles

Motivation of the need for equipment

The Particle Insight Shape Module is coupled in series with the Liquid Dispersion Module of the Mastersizer 3000 Particle Size Analyzer. The module complements the laser diffraction particle size data results of the Mastersizer 3000 analyzer and provides particle size distribution information to the particle images. , their quantitative data, data on the shape of particles. The advantages of this module include the provision of high-speed dynamic imaging technology with high resolution: a digital camera with a speed of up to 127 FPS and a resolution of up to 5 MP, obtaining images of individual particles and liquid dispersions of particles from 1 to 800 μm, the ability to create thumbnails of images, their save for review after run, obtain quantitative data on particle size and shape, including data on particle width and elongation.